Red Fluorescent SR In vivo Poly (active) Caspase (VAD) Assay

A non-cytotoxic, cell-permeant fluorescent inhibitor of caspases optimized for use in whole live animals. The probe contains the preferred binding sequence for most caspases (Val-Ala-Asp or VAD), coupled to a SR dye and a FMK reactive entity.



SKU: 982

Size: 6 Tests
Price:
Sale price$205.50

Similar to our FLICA® probes, but optimized for whole live animal imaging, SR in vivo probes are non-cytotoxic fluorescent inhibitors of caspases. ICT’s Red Fluorescent SR In vivo Poly (active) Caspase (VAD) Assay inhibitor probe contains the preferred binding sequence for all caspases, Val-Ala-Asp (VAD). This preferred poly caspase tripeptide binding sequence is labeled at the amino terminus end with a sulforhodamine B (SR) dye and linked at the carboxyl end to a fluoromethyl ketone (FMK) reactive entity. The resulting cell permeant, fluorescent molecule, SR-VAD-FMK, optimally excites at 550-580 nm and emits at 590-600 nm. The spectra for the probe is shown in Figure 1.

Apoptosis is an evolutionarily conserved process of programmed cell suicide. It is centered on a cascade of proteolytic enzymes called caspases that are triggered in response to pro-apoptotic signals. Like most other proteases, caspases are synthesized as pro-form precursors that undergo proteolytic maturation, either autocatalytically or in a cascade by enzymes with similar specificity. Active caspase enzymes consist of two large (~20 kD) and two small (~10 kD) subunits that non-covalently associate to form a two heterodimer, tetrameric active caspase. Once activated, caspases cleave protein substrates leading to the eventual disassembly of the cell. Caspases have been identified in organisms ranging from C. elegans to humans. Mammalian caspases play distinct roles in both apoptosis and inflammation.

The kit provides a simple yet accurate method to detect caspase activity in vivo. To label cells containing elevated levels of active caspases, inject the probe intravenously and let it circulate ~60 minutes. Because the reagent is cell-permeant, it readily diffuses in and out of all cells it encounters as it circulates throughout the body. If there are active caspase enzymes inside a cell, the reagent will form an irreversible covalent bond with a reactive cysteine on the large subunit of the caspase heterodimer, thereby inhibiting further enzymatic activity. The bound reagent probe will remain inside the cell as long as the cell membrane is intact. Any unbound probe is removed from the circulation of the animal in about an hour. Additional time may be needed for the probe to clear other tissues. The remaining red fluorescent signal in the tissue after unbound probe has cleared is a direct measure of caspase activity that occurred at the time the reagent was injected. Apoptotic cells will retain a higher concentration of the probe and fluoresce brighter than non-apoptotic cells. There is no interference from pro-caspases or inactive forms of the enzyme. If the treatment is causing cell death via apoptosis, apoptotic cells will have an elevated level of caspase activity relative to non-apoptotic or negative control cells and fluoresce red with the probe. After labeling with probe, excised tissues can be counter-stained with other reagents and fixed or frozen.

Once the animals have been injected with probe and excess unbound probe has cleared from the body of the animal, the tissues are ready for analysis and no further staining is necessary. Because the probe is a direct stain, it eliminates any false positives that may arise from manipulation of the tissue. This gives a true representation of the induction of apoptosis in vivo as a result of the experimental condition. Tissues can be viewed directly through a window chamber system or other accessible cavity, or thin tissue sections can be prepared after sacrificing the animal. Tissues labeled with probe can be counter-stained with other reagents such as DAPI and fixed or frozen for future analysis. The fluorescence intensity can be quantified by excising the tissue and analyzing cells with a flow cytometer. The probe optimally excites at 550-580 nm and has a peak emission at 590-600 nm (Figure 1).

SR-FLIVO® Poly Caspase Inhibitor (SR-VAD-FMK)
Poly Caspases
550-580 nm/590-600 nm
Fluorescence Microscope, Flow Cytometer, Window Chamber System
Whole live animal, excised tissue
2-8°C
Ships overnight (domestic), International Priority Shipping
United States
  1. Prepare samples and controls.
  2. Dilute 10X Injection Buffer 1:10 with 45 mL diH20.
  3. Reconstitute SR-FLIVO with 50 µL DMSO.
  4. Dilute SR-FLIVO 1:12 with 550 µL 1X Injection Buffer.
  5. Inject 100 µL intravenously.
  6. Let SR-FLIVO circulate 30-60 minutes.
  7. View live tumor through a window chamber using a fluorescence microscope.
  8. If not viewing directly, excise tissue.
  9. If desired, label with additional stains, such as Hoechst 33342, or an antibody.
  10. If desired, fix cells.
  11. Analyze with a fluorescence microscope, flow cytometer, or a window chamber system. SR-FLIVO excites at 550-580 nm and emits at 590-600 nm.
Kit 982 6 Tests:
  • SR-FLIVO® Poly Caspase Inhibitor (SR-VAD-FMK), 1 vial, #6219
  • 10X Injection Buffer, 5 mL, #6220
  • Kit Manual
  • Kit 983 24 Tests:
  • SR-FLIVO® Poly Caspase Inhibitor (SR-VAD-FMK), 4 vials, #6219
  • 10X Injection Buffer, 5 mL, #6220
  • Kit Manual
  • Thomas M, Davis T, Nell T, Sishi B, Engelbrecht A. Amino Acid Starvation Sensitizes Resistant Breast Cancer to Doxorubicin-Induced Cell Death. Front Cell Dev Biol. 2020 Oct 15;8:565915. doi: 10.3389/fcell.2020.565915. eCollection 2020. Full Text

    "The body weight of the mice was monitored twice weekly. To assess intratumour caspase cleavage, FLIVOTM in vivo apoptosis tracers (Immunochemistry Technologies LLC, MN, United States) were used. The SR FLIVOTM red dye was prepared according to the manufacturer’s protocol and 100 μl was injected into the tail vein of mice after appropriate treatments were completed. After 1 h, whole tumors were excised, digested and analyzed using flow cytometry on the BD FACSAria I."

    Kim JK, Byun MR, Maeng CH, Kim YR, Choi JW. Selective Targeting of Cancer Stem Cells (CSCs) Based on Photodynamic Therapy (PDT) Penetration Depth Inhibits Colon Polyp Formation in Mice. Cancers (Basel). 2020 Jan 14;12(1). pii: E203. doi: 10.3390/cancers12010203. Abstract

    Kuchay, S;Giorgi, C;Simoneschi, D;Pagan, J;Missiroli, S;Saraf, A;Florens, L;Washburn, MP;Collazo-Lorduy, A;Castillo-Martin, M;Cordon-Cardo, C;Sebti, SM;Pinton, P;Pagano, M. PTEN counteracts FBXL2 to promote IP3R3- and Ca(2+)-mediated apoptosis limiting tumour growth. Nature. 2017 June 22. doi: 10.1038/nature22965. https://www.nature.com/nature/journal/vaop/ncurrent/full/nature22965.html. Full Article

    Missiroli, S;Bonora, M;Patergnani, S;Poletti, F;Perrone, M;Gafà, R;Magri, E;Raimondi, A;Lanza, G;Tacchetti, C;Kroemer, G;Pandolfi, PP;Pinton, P;Giorgi, C. PML at Mitochondria-Associated Membranes Is Critical for the Repression of Autophagy and Cancer Development. Cell Report. 2016 August 30, Pages 2415-2427. doi:10.1016/j.celrep.2016.07.082. http://www.sciencedirect.com/science/article/pii/S2211124716310282. Full Article

    Bulk Order Red Fluorescent SR In vivo Poly (active) Caspase (VAD) Assay

    Related Products

    Recently viewed